1 // SPDX-License-Identifier: GPL-2.0-only
2 /*
3 * intel_soc_dts_thermal.c
4 * Copyright (c) 2014, Intel Corporation.
5 */
6
7 #define pr_fmt(fmt) KBUILD_MODNAME ": " fmt
8
9 #include <linux/acpi.h>
10 #include <linux/module.h>
11 #include <linux/interrupt.h>
12 #include <asm/cpu_device_id.h>
13 #include <asm/intel-family.h>
14 #include "intel_soc_dts_iosf.h"
15
16 #define CRITICAL_OFFSET_FROM_TJ_MAX 5000
17
18 static int crit_offset = CRITICAL_OFFSET_FROM_TJ_MAX;
19 module_param(crit_offset, int, 0644);
20 MODULE_PARM_DESC(crit_offset,
21 "Critical Temperature offset from tj max in millidegree Celsius.");
22
23 /* IRQ 86 is a fixed APIC interrupt for BYT DTS Aux threshold notifications */
24 #define BYT_SOC_DTS_APIC_IRQ 86
25
26 static int soc_dts_thres_gsi;
27 static int soc_dts_thres_irq;
28 static struct intel_soc_dts_sensors *soc_dts;
29
soc_irq_thread_fn(int irq,void * dev_data)30 static irqreturn_t soc_irq_thread_fn(int irq, void *dev_data)
31 {
32 pr_debug("proc_thermal_interrupt\n");
33 intel_soc_dts_iosf_interrupt_handler(soc_dts);
34
35 return IRQ_HANDLED;
36 }
37
38 static const struct x86_cpu_id soc_thermal_ids[] = {
39 X86_MATCH_INTEL_FAM6_MODEL(ATOM_SILVERMONT, BYT_SOC_DTS_APIC_IRQ),
40 {}
41 };
42 MODULE_DEVICE_TABLE(x86cpu, soc_thermal_ids);
43
intel_soc_thermal_init(void)44 static int __init intel_soc_thermal_init(void)
45 {
46 int err = 0;
47 const struct x86_cpu_id *match_cpu;
48
49 match_cpu = x86_match_cpu(soc_thermal_ids);
50 if (!match_cpu)
51 return -ENODEV;
52
53 /* Create a zone with 2 trips with marked as read only */
54 soc_dts = intel_soc_dts_iosf_init(INTEL_SOC_DTS_INTERRUPT_APIC, true,
55 crit_offset);
56 if (IS_ERR(soc_dts)) {
57 err = PTR_ERR(soc_dts);
58 return err;
59 }
60
61 soc_dts_thres_gsi = (int)match_cpu->driver_data;
62 if (soc_dts_thres_gsi) {
63 /*
64 * Note the flags here MUST match the firmware defaults, rather
65 * then the request_irq flags, otherwise we get an EBUSY error.
66 */
67 soc_dts_thres_irq = acpi_register_gsi(NULL, soc_dts_thres_gsi,
68 ACPI_LEVEL_SENSITIVE,
69 ACPI_ACTIVE_LOW);
70 if (soc_dts_thres_irq < 0) {
71 pr_warn("intel_soc_dts: Could not get IRQ for GSI %d, err %d\n",
72 soc_dts_thres_gsi, soc_dts_thres_irq);
73 soc_dts_thres_irq = 0;
74 }
75 }
76
77 if (soc_dts_thres_irq) {
78 err = request_threaded_irq(soc_dts_thres_irq, NULL,
79 soc_irq_thread_fn,
80 IRQF_TRIGGER_RISING | IRQF_ONESHOT,
81 "soc_dts", soc_dts);
82 if (err) {
83 /*
84 * Do not just error out because the user space thermal
85 * daemon such as DPTF may use polling instead of being
86 * interrupt driven.
87 */
88 pr_warn("request_threaded_irq ret %d\n", err);
89 }
90 }
91
92 return 0;
93 }
94
intel_soc_thermal_exit(void)95 static void __exit intel_soc_thermal_exit(void)
96 {
97 if (soc_dts_thres_irq) {
98 free_irq(soc_dts_thres_irq, soc_dts);
99 acpi_unregister_gsi(soc_dts_thres_gsi);
100 }
101 intel_soc_dts_iosf_exit(soc_dts);
102 }
103
104 module_init(intel_soc_thermal_init)
105 module_exit(intel_soc_thermal_exit)
106
107 MODULE_DESCRIPTION("Intel SoC DTS Thermal Driver");
108 MODULE_AUTHOR("Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>");
109 MODULE_LICENSE("GPL v2");
110