1**General Properties** 2 3What: /sys/class/power_supply/<supply_name>/manufacturer 4Date: May 2007 5Contact: linux-pm@vger.kernel.org 6Description: 7 Reports the name of the device manufacturer. 8 9 Access: Read 10 Valid values: Represented as string 11 12What: /sys/class/power_supply/<supply_name>/model_name 13Date: May 2007 14Contact: linux-pm@vger.kernel.org 15Description: 16 Reports the name of the device model. 17 18 Access: Read 19 Valid values: Represented as string 20 21What: /sys/class/power_supply/<supply_name>/serial_number 22Date: January 2008 23Contact: linux-pm@vger.kernel.org 24Description: 25 Reports the serial number of the device. 26 27 Access: Read 28 Valid values: Represented as string 29 30What: /sys/class/power_supply/<supply_name>/type 31Date: May 2010 32Contact: linux-pm@vger.kernel.org 33Description: 34 Describes the main type of the supply. 35 36 Access: Read 37 Valid values: "Battery", "UPS", "Mains", "USB", "Wireless" 38 39**Battery and USB properties** 40 41What: /sys/class/power_supply/<supply_name>/current_avg 42Date: May 2007 43Contact: linux-pm@vger.kernel.org 44Description: 45 Battery: 46 47 Reports an average IBAT current reading for the battery, over 48 a fixed period. Normally devices will provide a fixed interval 49 in which they average readings to smooth out the reported 50 value. 51 52 USB: 53 54 Reports an average IBUS current reading over a fixed period. 55 Normally devices will provide a fixed interval in which they 56 average readings to smooth out the reported value. 57 58 Access: Read 59 60 Valid values: Represented in microamps. Negative values are 61 used for discharging batteries, positive values for charging 62 batteries and for USB IBUS current. 63 64What: /sys/class/power_supply/<supply_name>/current_max 65Date: October 2010 66Contact: linux-pm@vger.kernel.org 67Description: 68 Battery: 69 70 Reports the maximum IBAT current allowed into the battery. 71 72 USB: 73 74 Reports the maximum IBUS current the supply can support. 75 76 Access: Read 77 Valid values: Represented in microamps 78 79What: /sys/class/power_supply/<supply_name>/current_now 80Date: May 2007 81Contact: linux-pm@vger.kernel.org 82Description: 83 84 Battery: 85 86 Reports an instant, single IBAT current reading for the 87 battery. This value is not averaged/smoothed. 88 89 Access: Read 90 91 USB: 92 93 Reports the IBUS current supplied now. This value is generally 94 read-only reporting, unless the 'online' state of the supply 95 is set to be programmable, in which case this value can be set 96 within the reported min/max range. 97 98 Access: Read, Write 99 100 Valid values: Represented in microamps. Negative values are 101 used for discharging batteries, positive values for charging 102 batteries and for USB IBUS current. 103 104What: /sys/class/power_supply/<supply_name>/temp 105Date: May 2007 106Contact: linux-pm@vger.kernel.org 107Description: 108 Battery: 109 110 Reports the current TBAT battery temperature reading. 111 112 USB: 113 114 Reports the current supply temperature reading. This would 115 normally be the internal temperature of the device itself 116 (e.g TJUNC temperature of an IC) 117 118 Access: Read 119 120 Valid values: Represented in 1/10 Degrees Celsius 121 122What: /sys/class/power_supply/<supply_name>/temp_alert_max 123Date: July 2012 124Contact: linux-pm@vger.kernel.org 125Description: 126 Battery: 127 128 Maximum TBAT temperature trip-wire value where the supply will 129 notify user-space of the event. 130 131 USB: 132 133 Maximum supply temperature trip-wire value where the supply 134 will notify user-space of the event. 135 136 This is normally used for the charging scenario where 137 user-space needs to know if the temperature has crossed an 138 upper threshold so it can take appropriate action (e.g. warning 139 user that the temperature is critically high, and charging has 140 stopped). 141 142 Access: Read 143 144 Valid values: Represented in 1/10 Degrees Celsius 145 146What: /sys/class/power_supply/<supply_name>/temp_alert_min 147Date: July 2012 148Contact: linux-pm@vger.kernel.org 149Description: 150 151 Battery: 152 153 Minimum TBAT temperature trip-wire value where the supply will 154 notify user-space of the event. 155 156 USB: 157 158 Minimum supply temperature trip-wire value where the supply 159 will notify user-space of the event. 160 161 This is normally used for the charging scenario where user-space 162 needs to know if the temperature has crossed a lower threshold 163 so it can take appropriate action (e.g. warning user that 164 temperature level is high, and charging current has been 165 reduced accordingly to remedy the situation). 166 167 Access: Read 168 169 Valid values: Represented in 1/10 Degrees Celsius 170 171What: /sys/class/power_supply/<supply_name>/temp_max 172Date: July 2014 173Contact: linux-pm@vger.kernel.org 174Description: 175 Battery: 176 177 Reports the maximum allowed TBAT battery temperature for 178 charging. 179 180 USB: 181 182 Reports the maximum allowed supply temperature for operation. 183 184 Access: Read 185 186 Valid values: Represented in 1/10 Degrees Celsius 187 188What: /sys/class/power_supply/<supply_name>/temp_min 189Date: July 2014 190Contact: linux-pm@vger.kernel.org 191Description: 192 Battery: 193 194 Reports the minimum allowed TBAT battery temperature for 195 charging. 196 197 USB: 198 199 Reports the minimum allowed supply temperature for operation. 200 201 Access: Read 202 203 Valid values: Represented in 1/10 Degrees Celsius 204 205What: /sys/class/power_supply/<supply_name>/voltage_max, 206Date: January 2008 207Contact: linux-pm@vger.kernel.org 208Description: 209 Battery: 210 211 Reports the maximum safe VBAT voltage permitted for the 212 battery, during charging. 213 214 USB: 215 216 Reports the maximum VBUS voltage the supply can support. 217 218 Access: Read 219 220 Valid values: Represented in microvolts 221 222What: /sys/class/power_supply/<supply_name>/voltage_min, 223Date: January 2008 224Contact: linux-pm@vger.kernel.org 225Description: 226 Battery: 227 228 Reports the minimum safe VBAT voltage permitted for the 229 battery, during discharging. 230 231 USB: 232 233 Reports the minimum VBUS voltage the supply can support. 234 235 Access: Read 236 237 Valid values: Represented in microvolts 238 239What: /sys/class/power_supply/<supply_name>/voltage_now, 240Date: May 2007 241Contact: linux-pm@vger.kernel.org 242Description: 243 Battery: 244 245 Reports an instant, single VBAT voltage reading for the 246 battery. This value is not averaged/smoothed. 247 248 Access: Read 249 250 USB: 251 252 Reports the VBUS voltage supplied now. This value is generally 253 read-only reporting, unless the 'online' state of the supply 254 is set to be programmable, in which case this value can be set 255 within the reported min/max range. 256 257 Access: Read, Write 258 259 Valid values: Represented in microvolts 260 261**Battery Properties** 262 263What: /sys/class/power_supply/<supply_name>/capacity 264Date: May 2007 265Contact: linux-pm@vger.kernel.org 266Description: 267 Fine grain representation of battery capacity. 268 269 Access: Read 270 271 Valid values: 0 - 100 (percent) 272 273What: /sys/class/power_supply/<supply_name>/capacity_alert_max 274Date: July 2012 275Contact: linux-pm@vger.kernel.org 276Description: 277 Maximum battery capacity trip-wire value where the supply will 278 notify user-space of the event. This is normally used for the 279 battery discharging scenario where user-space needs to know the 280 battery has dropped to an upper level so it can take 281 appropriate action (e.g. warning user that battery level is 282 low). 283 284 Access: Read, Write 285 286 Valid values: 0 - 100 (percent) 287 288What: /sys/class/power_supply/<supply_name>/capacity_alert_min 289Date: July 2012 290Contact: linux-pm@vger.kernel.org 291Description: 292 Minimum battery capacity trip-wire value where the supply will 293 notify user-space of the event. This is normally used for the 294 battery discharging scenario where user-space needs to know the 295 battery has dropped to a lower level so it can take 296 appropriate action (e.g. warning user that battery level is 297 critically low). 298 299 Access: Read, Write 300 301 Valid values: 0 - 100 (percent) 302 303What: /sys/class/power_supply/<supply_name>/capacity_error_margin 304Date: April 2019 305Contact: linux-pm@vger.kernel.org 306Description: 307 Battery capacity measurement becomes unreliable without 308 recalibration. This values provides the maximum error 309 margin expected to exist by the fuel gauge in percent. 310 Values close to 0% will be returned after (re-)calibration 311 has happened. Over time the error margin will increase. 312 100% means, that the capacity related values are basically 313 completely useless. 314 315 Access: Read 316 317 Valid values: 0 - 100 (percent) 318 319What: /sys/class/power_supply/<supply_name>/capacity_level 320Date: June 2009 321Contact: linux-pm@vger.kernel.org 322Description: 323 Coarse representation of battery capacity. 324 325 Access: Read 326 327 Valid values: 328 "Unknown", "Critical", "Low", "Normal", "High", 329 "Full" 330 331What: /sys/class/power_supply/<supply_name>/charge_control_limit 332Date: Oct 2012 333Contact: linux-pm@vger.kernel.org 334Description: 335 Maximum allowable charging current. Used for charge rate 336 throttling for thermal cooling or improving battery health. 337 338 Access: Read, Write 339 340 Valid values: Represented in microamps 341 342What: /sys/class/power_supply/<supply_name>/charge_control_limit_max 343Date: Oct 2012 344Contact: linux-pm@vger.kernel.org 345Description: 346 Maximum legal value for the charge_control_limit property. 347 348 Access: Read 349 350 Valid values: Represented in microamps 351 352What: /sys/class/power_supply/<supply_name>/charge_control_start_threshold 353Date: April 2019 354Contact: linux-pm@vger.kernel.org 355Description: 356 Represents a battery percentage level, below which charging will 357 begin. 358 359 Access: Read, Write 360 Valid values: 0 - 100 (percent) 361 362What: /sys/class/power_supply/<supply_name>/charge_control_end_threshold 363Date: April 2019 364Contact: linux-pm@vger.kernel.org 365Description: 366 Represents a battery percentage level, above which charging will 367 stop. Not all hardware is capable of setting this to an arbitrary 368 percentage. Drivers will round written values to the nearest 369 supported value. Reading back the value will show the actual 370 threshold set by the driver. 371 372 Access: Read, Write 373 374 Valid values: 0 - 100 (percent) 375 376What: /sys/class/power_supply/<supply_name>/charge_type 377Date: July 2009 378Contact: linux-pm@vger.kernel.org 379Description: 380 Represents the type of charging currently being applied to the 381 battery. "Trickle", "Fast", and "Standard" all mean different 382 charging speeds. "Adaptive" means that the charger uses some 383 algorithm to adjust the charge rate dynamically, without 384 any user configuration required. "Custom" means that the charger 385 uses the charge_control_* properties as configuration for some 386 different algorithm. "Long Life" means the charger reduces its 387 charging rate in order to prolong the battery health. "Bypass" 388 means the charger bypasses the charging path around the 389 integrated converter allowing for a "smart" wall adaptor to 390 perform the power conversion externally. 391 392 Access: Read, Write 393 394 Valid values: 395 "Unknown", "N/A", "Trickle", "Fast", "Standard", 396 "Adaptive", "Custom", "Long Life", "Bypass" 397 398What: /sys/class/power_supply/<supply_name>/charge_term_current 399Date: July 2014 400Contact: linux-pm@vger.kernel.org 401Description: 402 Reports the charging current value which is used to determine 403 when the battery is considered full and charging should end. 404 405 Access: Read 406 407 Valid values: Represented in microamps 408 409What: /sys/class/power_supply/<supply_name>/health 410Date: May 2007 411Contact: linux-pm@vger.kernel.org 412Description: 413 Reports the health of the battery or battery side of charger 414 functionality. 415 416 Access: Read 417 418 Valid values: 419 "Unknown", "Good", "Overheat", "Dead", 420 "Over voltage", "Unspecified failure", "Cold", 421 "Watchdog timer expire", "Safety timer expire", 422 "Over current", "Calibration required", "Warm", 423 "Cool", "Hot", "No battery" 424 425What: /sys/class/power_supply/<supply_name>/precharge_current 426Date: June 2017 427Contact: linux-pm@vger.kernel.org 428Description: 429 Reports the charging current applied during pre-charging phase 430 for a battery charge cycle. 431 432 Access: Read 433 434 Valid values: Represented in microamps 435 436What: /sys/class/power_supply/<supply_name>/present 437Date: May 2007 438Contact: linux-pm@vger.kernel.org 439Description: 440 Reports whether a battery is present or not in the system. 441 442 Access: Read 443 444 Valid values: 445 446 == ======= 447 0: Absent 448 1: Present 449 == ======= 450 451What: /sys/class/power_supply/<supply_name>/status 452Date: May 2007 453Contact: linux-pm@vger.kernel.org 454Description: 455 Represents the charging status of the battery. Normally this 456 is read-only reporting although for some supplies this can be 457 used to enable/disable charging to the battery. 458 459 Access: Read, Write 460 461 Valid values: 462 "Unknown", "Charging", "Discharging", 463 "Not charging", "Full" 464 465What: /sys/class/power_supply/<supply_name>/charge_behaviour 466Date: November 2021 467Contact: linux-pm@vger.kernel.org 468Description: 469 Represents the charging behaviour. 470 471 Access: Read, Write 472 473 Valid values: 474 ================ ==================================== 475 auto: Charge normally, respect thresholds 476 inhibit-charge: Do not charge while AC is attached 477 force-discharge: Force discharge while AC is attached 478 ================ ==================================== 479 480What: /sys/class/power_supply/<supply_name>/technology 481Date: May 2007 482Contact: linux-pm@vger.kernel.org 483Description: 484 Describes the battery technology supported by the supply. 485 486 Access: Read 487 488 Valid values: 489 "Unknown", "NiMH", "Li-ion", "Li-poly", "LiFe", 490 "NiCd", "LiMn" 491 492 493What: /sys/class/power_supply/<supply_name>/voltage_avg, 494Date: May 2007 495Contact: linux-pm@vger.kernel.org 496Description: 497 Reports an average VBAT voltage reading for the battery, over a 498 fixed period. Normally devices will provide a fixed interval in 499 which they average readings to smooth out the reported value. 500 501 Access: Read 502 503 Valid values: Represented in microvolts 504 505What: /sys/class/power_supply/<supply_name>/cycle_count 506Date: January 2010 507Contact: linux-pm@vger.kernel.org 508Description: 509 Reports the number of full charge + discharge cycles the 510 battery has undergone. 511 512 Access: Read 513 514 Valid values: 515 Integer > 0: representing full cycles 516 Integer = 0: cycle_count info is not available 517 518**USB Properties** 519 520What: /sys/class/power_supply/<supply_name>/input_current_limit 521Date: July 2014 522Contact: linux-pm@vger.kernel.org 523Description: 524 Details the incoming IBUS current limit currently set in the 525 supply. Normally this is configured based on the type of 526 connection made (e.g. A configured SDP should output a maximum 527 of 500mA so the input current limit is set to the same value). 528 Use preferably input_power_limit, and for problems that can be 529 solved using power limit use input_current_limit. 530 531 Access: Read, Write 532 533 Valid values: Represented in microamps 534 535What: /sys/class/power_supply/<supply_name>/input_voltage_limit 536Date: May 2019 537Contact: linux-pm@vger.kernel.org 538Description: 539 This entry configures the incoming VBUS voltage limit currently 540 set in the supply. Normally this is configured based on 541 system-level knowledge or user input (e.g. This is part of the 542 Pixel C's thermal management strategy to effectively limit the 543 input power to 5V when the screen is on to meet Google's skin 544 temperature targets). Note that this feature should not be 545 used for safety critical things. 546 Use preferably input_power_limit, and for problems that can be 547 solved using power limit use input_voltage_limit. 548 549 Access: Read, Write 550 551 Valid values: Represented in microvolts 552 553What: /sys/class/power_supply/<supply_name>/input_power_limit 554Date: May 2019 555Contact: linux-pm@vger.kernel.org 556Description: 557 This entry configures the incoming power limit currently set 558 in the supply. Normally this is configured based on 559 system-level knowledge or user input. Use preferably this 560 feature to limit the incoming power and use current/voltage 561 limit only for problems that can be solved using power limit. 562 563 Access: Read, Write 564 565 Valid values: Represented in microwatts 566 567What: /sys/class/power_supply/<supply_name>/online, 568Date: May 2007 569Contact: linux-pm@vger.kernel.org 570Description: 571 Indicates if VBUS is present for the supply. When the supply is 572 online, and the supply allows it, then it's possible to switch 573 between online states (e.g. Fixed -> Programmable for a PD_PPS 574 USB supply so voltage and current can be controlled). 575 576 Access: Read, Write 577 578 Valid values: 579 580 == ================================================== 581 0: Offline 582 1: Online Fixed - Fixed Voltage Supply 583 2: Online Programmable - Programmable Voltage Supply 584 == ================================================== 585 586What: /sys/class/power_supply/<supply_name>/usb_type 587Date: March 2018 588Contact: linux-pm@vger.kernel.org 589Description: 590 Reports what type of USB connection is currently active for 591 the supply, for example it can show if USB-PD capable source 592 is attached. 593 594 Access: Read-Only 595 596 Valid values: 597 "Unknown", "SDP", "DCP", "CDP", "ACA", "C", "PD", 598 "PD_DRP", "PD_PPS", "BrickID" 599 600**Device Specific Properties** 601 602What: /sys/class/power/ds2760-battery.*/charge_now 603Date: May 2010 604KernelVersion: 2.6.35 605Contact: Daniel Mack <daniel@caiaq.de> 606Description: 607 This file is writeable and can be used to set the current 608 coloumb counter value inside the battery monitor chip. This 609 is needed for unavoidable corrections of aging batteries. 610 A userspace daemon can monitor the battery charging logic 611 and once the counter drops out of considerable bounds, take 612 appropriate action. 613 614What: /sys/class/power/ds2760-battery.*/charge_full 615Date: May 2010 616KernelVersion: 2.6.35 617Contact: Daniel Mack <daniel@caiaq.de> 618Description: 619 This file is writeable and can be used to set the assumed 620 battery 'full level'. As batteries age, this value has to be 621 amended over time. 622 623What: /sys/class/power_supply/max14577-charger/device/fast_charge_timer 624Date: October 2014 625KernelVersion: 3.18.0 626Contact: Krzysztof Kozlowski <krzk@kernel.org> 627Description: 628 This entry shows and sets the maximum time the max14577 629 charger operates in fast-charge mode. When the timer expires 630 the device will terminate fast-charge mode (charging current 631 will drop to 0 A) and will trigger interrupt. 632 633 Valid values: 634 635 - 5, 6 or 7 (hours), 636 - 0: disabled. 637 638What: /sys/class/power_supply/max77693-charger/device/fast_charge_timer 639Date: January 2015 640KernelVersion: 3.19.0 641Contact: Krzysztof Kozlowski <krzk@kernel.org> 642Description: 643 This entry shows and sets the maximum time the max77693 644 charger operates in fast-charge mode. When the timer expires 645 the device will terminate fast-charge mode (charging current 646 will drop to 0 A) and will trigger interrupt. 647 648 Valid values: 649 650 - 4 - 16 (hours), step by 2 (rounded down) 651 - 0: disabled. 652 653What: /sys/class/power_supply/max77693-charger/device/top_off_threshold_current 654Date: January 2015 655KernelVersion: 3.19.0 656Contact: Krzysztof Kozlowski <krzk@kernel.org> 657Description: 658 This entry shows and sets the charging current threshold for 659 entering top-off charging mode. When charging current in fast 660 charge mode drops below this value, the charger will trigger 661 interrupt and start top-off charging mode. 662 663 Valid values: 664 665 - 100000 - 200000 (microamps), step by 25000 (rounded down) 666 - 200000 - 350000 (microamps), step by 50000 (rounded down) 667 - 0: disabled. 668 669What: /sys/class/power_supply/max77693-charger/device/top_off_timer 670Date: January 2015 671KernelVersion: 3.19.0 672Contact: Krzysztof Kozlowski <krzk@kernel.org> 673Description: 674 This entry shows and sets the maximum time the max77693 675 charger operates in top-off charge mode. When the timer expires 676 the device will terminate top-off charge mode (charging current 677 will drop to 0 A) and will trigger interrupt. 678 679 Valid values: 680 681 - 0 - 70 (minutes), step by 10 (rounded down) 682 683What: /sys/class/power_supply/bq24257-charger/ovp_voltage 684Date: October 2015 685KernelVersion: 4.4.0 686Contact: Andreas Dannenberg <dannenberg@ti.com> 687Description: 688 This entry configures the overvoltage protection feature of bq24257- 689 type charger devices. This feature protects the device and other 690 components against damage from overvoltage on the input supply. See 691 device datasheet for details. 692 693 Valid values: 694 695 - 6000000, 6500000, 7000000, 8000000, 9000000, 9500000, 10000000, 696 10500000 (all uV) 697 698What: /sys/class/power_supply/bq24257-charger/in_dpm_voltage 699Date: October 2015 700KernelVersion: 4.4.0 701Contact: Andreas Dannenberg <dannenberg@ti.com> 702Description: 703 This entry configures the input dynamic power path management voltage of 704 bq24257-type charger devices. Once the supply drops to the configured 705 voltage, the input current limit is reduced down to prevent the further 706 drop of the supply. When the IC enters this mode, the charge current is 707 lower than the set value. See device datasheet for details. 708 709 Valid values: 710 711 - 4200000, 4280000, 4360000, 4440000, 4520000, 4600000, 4680000, 712 4760000 (all uV) 713 714What: /sys/class/power_supply/bq24257-charger/high_impedance_enable 715Date: October 2015 716KernelVersion: 4.4.0 717Contact: Andreas Dannenberg <dannenberg@ti.com> 718Description: 719 This entry allows enabling the high-impedance mode of bq24257-type 720 charger devices. If enabled, it places the charger IC into low power 721 standby mode with the switch mode controller disabled. When disabled, 722 the charger operates normally. See device datasheet for details. 723 724 Valid values: 725 726 - 1: enabled 727 - 0: disabled 728 729What: /sys/class/power_supply/bq24257-charger/sysoff_enable 730Date: October 2015 731KernelVersion: 4.4.0 732Contact: Andreas Dannenberg <dannenberg@ti.com> 733Description: 734 This entry allows enabling the sysoff mode of bq24257-type charger 735 devices. If enabled and the input is removed, the internal battery FET 736 is turned off in order to reduce the leakage from the BAT pin to less 737 than 1uA. Note that on some devices/systems this disconnects the battery 738 from the system. See device datasheet for details. 739 740 Valid values: 741 742 - 1: enabled 743 - 0: disabled 744 745What: /sys/class/power_supply/<supply_name>/manufacture_year 746Date: January 2020 747Contact: linux-pm@vger.kernel.org 748Description: 749 Reports the year (following Gregorian calendar) when the device has been 750 manufactured. 751 752 Access: Read 753 754 Valid values: Reported as integer 755 756What: /sys/class/power_supply/<supply_name>/manufacture_month 757Date: January 2020 758Contact: linux-pm@vger.kernel.org 759Description: 760 Reports the month when the device has been manufactured. 761 762 Access: Read 763 764 Valid values: 1-12 765 766What: /sys/class/power_supply/<supply_name>/manufacture_day 767Date: January 2020 768Contact: linux-pm@vger.kernel.org 769Description: 770 Reports the day of month when the device has been manufactured. 771 772 Access: Read 773 Valid values: 1-31 774