1What:		/sys/bus/iio/devices/iio:deviceX/in_concentration_co2_calibration_factory
2Date:		August 2021
3KernelVersion:	5.16
4Contact:	Jacopo Mondi <jacopo@jmondi.org>
5Description:
6		Writing '1' triggers a 'Factory' calibration cycle.
7
8What:		/sys/bus/iio/devices/iio:deviceX/in_concentration_co2_calibration_background
9Date:		August 2021
10KernelVersion:	5.16
11Contact:	Jacopo Mondi <jacopo@jmondi.org>
12Description:
13		Writing '1' triggers a 'Background' calibration cycle.
14
15What:		/sys/bus/iio/devices/iio:deviceX/error_status_available
16Date:		August 2021
17KernelVersion:	5.16
18Contact:	Jacopo Mondi <jacopo@jmondi.org>
19Description:
20		Reading returns the list of possible chip error status.
21		Available options are:
22		- 'error_fatal': Analog front-end initialization error
23		- 'error_i2c': Read/write to non-existing register
24		- 'error_algorithm': Corrupted parameters
25		- 'error_calibration': Calibration has failed
26		- 'error_self_diagnostic': Internal interface failure
27		- 'error_out_of_range': Measured concentration out of scale
28		- 'error_memory': Error during memory operations
29		- 'error_no_measurement': Cleared at first measurement
30		- 'error_low_voltage': Sensor regulated voltage too low
31		- 'error_measurement_timeout': Unable to complete measurement
32
33What:		/sys/bus/iio/devices/iio:deviceX/error_status
34Date:		August 2021
35KernelVersion:	5.16
36Contact:	Jacopo Mondi <jacopo@jmondi.org>
37Description:
38		Reading returns the current chip error status.
39