1Socionext Milbeaut UART controller
2
3Required properties:
4- compatible: should be "socionext,milbeaut-usio-uart".
5- reg: offset and length of the register set for the device.
6- interrupts: two interrupts specifier.
7- interrupt-names: should be "rx", "tx".
8- clocks: phandle to the input clock.
9
10Optional properties:
11- auto-flow-control: flow control enable.
12
13Example:
14	usio1: usio_uart@1e700010 {
15		compatible = "socionext,milbeaut-usio-uart";
16		reg = <0x1e700010 0x10>;
17		interrupts = <0 141 0x4>, <0 149 0x4>;
18		interrupt-names = "rx", "tx";
19		clocks = <&clk 2>;
20		auto-flow-control;
21	};
22