Searched refs:connected_addr (Results 1 – 6 of 6) sorted by relevance
/linux-6.6.21/net/wireless/ |
D | sme.c | 761 const u8 *connected_addr; in __cfg80211_connect_result() local 786 connected_addr = cr->valid_links ? cr->ap_mld_addr : cr->links[0].bssid; in __cfg80211_connect_result() 806 if (connected_addr && cr->status == WLAN_STATUS_SUCCESS) { in __cfg80211_connect_result() 807 memcpy(wrqu.ap_addr.sa_data, connected_addr, ETH_ALEN); in __cfg80211_connect_result() 808 memcpy(wdev->wext.prev_bssid, connected_addr, ETH_ALEN); in __cfg80211_connect_result() 879 ether_addr_copy(wdev->u.client.connected_addr, connected_addr); in __cfg80211_connect_result() 1094 const u8 *connected_addr; in __cfg80211_roamed() local 1130 connected_addr = info->valid_links ? in __cfg80211_roamed() 1133 ether_addr_copy(wdev->u.client.connected_addr, connected_addr); in __cfg80211_roamed() 1161 memcpy(wrqu.ap_addr.sa_data, connected_addr, ETH_ALEN); in __cfg80211_roamed() [all …]
|
D | mlme.c | 121 if (!wdev->connected || !ether_addr_equal(wdev->u.client.connected_addr, bssid)) in cfg80211_process_deauth() 142 !ether_addr_equal(wdev->u.client.connected_addr, bssid))) in cfg80211_process_disassoc() 283 ether_addr_equal(req->bss->bssid, wdev->u.client.connected_addr)) in cfg80211_mlme_auth() 352 !ether_addr_equal(wdev->u.client.connected_addr, req->prev_bssid))) in cfg80211_mlme_assoc() 402 !ether_addr_equal(wdev->u.client.connected_addr, bssid))) in cfg80211_mlme_deauth() 407 ether_addr_equal(wdev->u.client.connected_addr, bssid))) in cfg80211_mlme_deauth() 433 if (memcmp(wdev->u.client.connected_addr, ap_addr, ETH_ALEN)) in cfg80211_mlme_disassoc() 459 memcpy(bssid, wdev->u.client.connected_addr, ETH_ALEN); in cfg80211_mlme_down() 777 if (!ether_addr_equal(wdev->u.client.connected_addr, in cfg80211_mlme_mgmt_tx() 784 if (!ether_addr_equal(wdev->u.client.connected_addr, in cfg80211_mlme_mgmt_tx()
|
D | nl80211.c | 10424 wdev->u.client.connected_addr))))) in nl80211_send_bss() 15553 if (memcmp(pmk_conf.aa, wdev->u.client.connected_addr, ETH_ALEN)) { in nl80211_set_pmk() 18058 const u8 *connected_addr = cr->valid_links ? in nl80211_send_connect_result() local 18091 (connected_addr && in nl80211_send_connect_result() 18092 nla_put(msg, NL80211_ATTR_MAC, ETH_ALEN, connected_addr)) || in nl80211_send_connect_result() 18170 const u8 *connected_addr = info->ap_mld_addr ? in nl80211_send_roamed() local 18205 nla_put(msg, NL80211_ATTR_MAC, ETH_ALEN, connected_addr) || in nl80211_send_roamed()
|
/linux-6.6.21/include/uapi/linux/ |
D | rds.h | 200 __be32 connected_addr; member 210 struct in6_addr connected_addr; member
|
/linux-6.6.21/net/rds/ |
D | af_rds.c | 823 sinfo.connected_addr = rs->rs_conn_addr_v4; in rds_sock_info() 858 sinfo6.connected_addr = rs->rs_conn_addr; in rds6_sock_info()
|
/linux-6.6.21/include/net/ |
D | cfg80211.h | 6049 u8 connected_addr[ETH_ALEN] __aligned(2); member
|