Searched refs:related_cpus (Results 1 – 17 of 17) sorted by relevance
/linux-6.1.9/drivers/thermal/ ! |
D | cpufreq_cooling.c | 229 for_each_cpu(cpu, policy->related_cpus) { in cpufreq_get_requested_power() 309 trace_thermal_power_cpu_limit(policy->related_cpus, target_freq, *state, in cpufreq_power2state() 323 if (!cpumask_equal(policy->related_cpus, em_span_cpus(em))) { in em_is_sane() 326 cpumask_pr_args(policy->related_cpus)); in em_is_sane() 354 unsigned int num_cpus = cpumask_weight(cpufreq_cdev->policy->related_cpus); in allocate_idle_time() 468 cpus = cpufreq_cdev->policy->related_cpus; in cpufreq_set_cur_state()
|
/linux-6.1.9/drivers/powercap/ ! |
D | dtpm_cpu.c | 145 for_each_cpu(dtpm_cpu->cpu, policy->related_cpus) in pd_release() 208 for_each_cpu(cpu, policy->related_cpus) in __dtpm_cpu_setup() 230 for_each_cpu(cpu, policy->related_cpus) in __dtpm_cpu_setup()
|
/linux-6.1.9/drivers/cpufreq/ ! |
D | qcom-cpufreq-hw.c | 119 for (i = 1; i < cpumask_weight(policy->related_cpus); i++) in qcom_cpufreq_hw_target_index() 188 for (i = 1; i < cpumask_weight(policy->related_cpus); i++) in qcom_cpufreq_hw_fast_switch() 321 int cpu = cpumask_first(policy->related_cpus); in qcom_lmh_dcvs_notify() 347 arch_update_thermal_pressure(policy->related_cpus, throttled_freq); in qcom_lmh_dcvs_notify() 636 dev_pm_opp_of_cpumask_remove_table(policy->related_cpus); in qcom_cpufreq_hw_cpu_exit()
|
D | cpufreq.c | 449 arch_set_freq_scale(policy->related_cpus, in cpufreq_freq_transition_end() 865 return cpufreq_show_cpus(policy->related_cpus, buf); in show_related_cpus() 923 cpufreq_freq_attr_ro(related_cpus); 937 &related_cpus.attr, 1204 if (!zalloc_cpumask_var(&policy->related_cpus, GFP_KERNEL)) in cpufreq_policy_alloc() 1262 free_cpumask_var(policy->related_cpus); in cpufreq_policy_alloc() 1287 for_each_cpu(cpu, policy->related_cpus) in cpufreq_policy_free() 1315 free_cpumask_var(policy->related_cpus); in cpufreq_policy_free() 1333 WARN_ON(!cpumask_test_cpu(cpu, policy->related_cpus)); in cpufreq_online() 1352 cpumask_copy(policy->cpus, policy->related_cpus); in cpufreq_online() [all …]
|
D | cpufreq_governor.c | 367 for_each_cpu(j, policy->related_cpus) { in alloc_policy_dbs_info() 382 for_each_cpu(j, policy_dbs->policy->related_cpus) { in free_policy_dbs_info()
|
D | cppc_cpufreq.c | 214 topology_clear_scale_freq_source(SCALE_FREQ_SOURCE_CPPC, policy->related_cpus); in cppc_cpufreq_cpu_fie_exit() 216 for_each_cpu(cpu, policy->related_cpus) { in cppc_cpufreq_cpu_fie_exit()
|
D | vexpress-spc-cpufreq.c | 462 put_cluster_clk_and_freq_table(cpu_dev, policy->related_cpus); in ve_spc_cpufreq_exit()
|
/linux-6.1.9/drivers/acpi/ ! |
D | processor_thermal.c | 133 for_each_cpu(cpu, policy->related_cpus) { in acpi_thermal_cpufreq_init() 153 for_each_cpu(cpu, policy->related_cpus) { in acpi_thermal_cpufreq_exit()
|
D | processor_perflib.c | 161 for_each_cpu(cpu, policy->related_cpus) { in acpi_processor_ppc_init() 181 for_each_cpu(cpu, policy->related_cpus) { in acpi_processor_ppc_exit()
|
/linux-6.1.9/drivers/base/ ! |
D | arch_topology.c | 408 cpumask_pr_args(policy->related_cpus), in init_cpu_capacity_callback() 411 cpumask_andnot(cpus_to_visit, cpus_to_visit, policy->related_cpus); in init_cpu_capacity_callback() 413 for_each_cpu(cpu, policy->related_cpus) in init_cpu_capacity_callback()
|
/linux-6.1.9/Documentation/admin-guide/pm/ ! |
D | cpufreq_drivers.rst | 108 2.4 related_cpus 259 2.4 related_cpus: 261 The related_cpus field is identical to affected_cpus. 264 related_cpus : 4
|
D | cpufreq.rst | 267 ``related_cpus``
|
/linux-6.1.9/drivers/devfreq/ ! |
D | governor_passive.c | 30 if (parent_cpu_data->first_cpu == cpumask_first(policy->related_cpus)) in get_parent_cpu_data() 311 parent_cpu_data->first_cpu = cpumask_first(policy->related_cpus); in cpufreq_passive_register_notifier()
|
/linux-6.1.9/arch/arm64/kernel/ ! |
D | topology.c | 219 amu_fie_setup(policy->related_cpus); in init_amu_fie_callback()
|
/linux-6.1.9/kernel/sched/ ! |
D | cpufreq_schedutil.c | 602 cpumask_first(policy->related_cpus)); in sugov_kthread_create() 616 kthread_bind_mask(thread, policy->related_cpus); in sugov_kthread_create()
|
/linux-6.1.9/include/linux/ ! |
D | cpufreq.h | 58 cpumask_var_t related_cpus; /* Online + Offline CPUs */ member 1226 policy->related_cpus); in cpufreq_register_em_with_opp()
|
/linux-6.1.9/Documentation/ABI/testing/ ! |
D | sysfs-devices-system-cpu | 264 value of related_cpus may be different from freqdomain_cpus. This
|