Searched refs:Shutdown (Results 1 – 25 of 37) sorted by relevance
12
/linux-6.1.9/Documentation/devicetree/bindings/clock/ |
D | idt,versaclock5.yaml | 34 SH (en_global_shutdown) and SP bits of the Primary Source and Shutdown 42 1 0 Active/Shutdown 43 1 1 Inactive/Shutdown 90 bit of the Primary Source and Shutdown Register. 100 Shutdown Register.
|
/linux-6.1.9/Documentation/sound/soc/ |
D | pops-clicks.rst | 28 Shutdown Order :- Digital Mute --> Output PGA --> Mixers --> DAC 45 Shutdown Order - ADC --> Mixers --> Input PGA
|
/linux-6.1.9/Documentation/ABI/testing/ |
D | sysfs-driver-input-axp-pek | 10 Description: Shutdown time in us. Board is powered off if the button is pressed
|
D | sysfs-class-mic | 85 "crashed" Shutdown because of a HW or SW crash. 86 "halted" Shutdown because of a halt command. 87 "poweroff" Shutdown because of a poweroff command. 88 "restart" Shutdown because of a restart command.
|
/linux-6.1.9/Documentation/hwmon/ |
D | thmc50.rst | 47 sensors, limits can be set through the appropriate Overtemperature Shutdown 50 temperature gets higher then the Overtemperature Shutdown value; it stays on
|
D | tmp102.rst | 22 set through the Overtemperature Shutdown register and Hysteresis register. The
|
D | lm78.rst | 46 when the Overtemperature Shutdown limit is crossed; it is triggered again 50 is above the Overtemperature Shutdown value. Measurements are guaranteed
|
D | lm75.rst | 142 Overtemperature Shutdown register and Hysteresis register. Each value can be 145 gets higher then the Overtemperature Shutdown value; it stays on until
|
D | lm80.rst | 46 drops below the HOT Hysteresis. The Overtemperature Shutdown (OS) limits
|
D | via686a.rst | 49 when the Overtemperature Shutdown limit is crossed; it is triggered again
|
D | abituguru-datasheet.rst | 245 - Volt sensor: Shutdown if alarm persist for more than 4 seconds (RW) 246 - Temp sensor: Shutdown if temp is over the shutdown threshold (RW) 320 Shutdown if alarm persist for more than 4 seconds (RW)
|
D | w83781d.rst | 104 Overtemperature Shutdown limit is crossed; it is triggered again as soon as 108 is above the Overtemperature Shutdown value. The driver sets the 112 temperature gets higher then the Overtemperature Shutdown value; it stays
|
D | w83791d.rst | 77 the temperature gets higher than the Overtemperature Shutdown value; it stays
|
D | w83792d.rst | 60 the temperature gets higher than the Overtemperature Shutdown value; it stays
|
/linux-6.1.9/Documentation/driver-api/thermal/ |
D | nouveau_thermal.rst | 37 * Shutdown: 50 * Shutdown: temp1_emergency and temp1_emergency_hyst.
|
/linux-6.1.9/Documentation/devicetree/bindings/sound/ |
D | qcom,wsa881x.yaml | 26 description: GPIO spec for Powerdown/Shutdown line to use
|
D | qcom,wsa883x.yaml | 26 description: GPIO spec for Powerdown/Shutdown line to use
|
/linux-6.1.9/Documentation/devicetree/bindings/arm/ |
D | atmel-sysregs.txt | 55 SHDWC Shutdown Controller 86 SHDWC SAMA5D2-Compatible Shutdown Controller
|
/linux-6.1.9/arch/mips/include/asm/mach-loongson64/ |
D | boot_param.h | 177 u64 Shutdown; member
|
/linux-6.1.9/arch/mips/loongson64/ |
D | env.c | 154 loongson_sysconf.poweroff_addr = boot_p->reset_system.Shutdown; in prom_lefi_init_env()
|
/linux-6.1.9/Documentation/devicetree/bindings/remoteproc/ |
D | qcom,sc7280-wpss-pil.yaml | 33 - description: Shutdown acknowledge interrupt
|
D | qcom,sc7180-mss-pil.yaml | 43 - description: Shutdown acknowledge interrupt
|
D | qcom,sc7280-mss-pil.yaml | 47 - description: Shutdown acknowledge interrupt
|
/linux-6.1.9/Documentation/devicetree/bindings/iio/adc/ |
D | adi,ad7606.yaml | 59 Shutdown mode. As the line is active low, it should be marked
|
/linux-6.1.9/drivers/media/tuners/ |
D | mt2063.c | 1345 static u32 MT2063_SoftwareShutdown(struct mt2063_state *state, u8 Shutdown) in MT2063_SoftwareShutdown() argument 1350 if (Shutdown == 1) in MT2063_SoftwareShutdown() 1359 if (Shutdown != 1) { in MT2063_SoftwareShutdown()
|
12