1 /* SPDX-License-Identifier: GPL-2.0 */
2 #ifndef _LINUX_SCHED_TOPOLOGY_H
3 #define _LINUX_SCHED_TOPOLOGY_H
4 
5 #include <linux/topology.h>
6 
7 #include <linux/sched/idle.h>
8 
9 /*
10  * sched-domains (multiprocessor balancing) declarations:
11  */
12 #ifdef CONFIG_SMP
13 
14 /* Generate SD flag indexes */
15 #define SD_FLAG(name, mflags) __##name,
16 enum {
17 	#include <linux/sched/sd_flags.h>
18 	__SD_FLAG_CNT,
19 };
20 #undef SD_FLAG
21 /* Generate SD flag bits */
22 #define SD_FLAG(name, mflags) name = 1 << __##name,
23 enum {
24 	#include <linux/sched/sd_flags.h>
25 };
26 #undef SD_FLAG
27 
28 #ifdef CONFIG_SCHED_DEBUG
29 
30 struct sd_flag_debug {
31 	unsigned int meta_flags;
32 	char *name;
33 };
34 extern const struct sd_flag_debug sd_flag_debug[];
35 
36 #endif
37 
38 #ifdef CONFIG_SCHED_SMT
cpu_smt_flags(void)39 static inline int cpu_smt_flags(void)
40 {
41 	return SD_SHARE_CPUCAPACITY | SD_SHARE_PKG_RESOURCES;
42 }
43 #endif
44 
45 #ifdef CONFIG_SCHED_CLUSTER
cpu_cluster_flags(void)46 static inline int cpu_cluster_flags(void)
47 {
48 	return SD_SHARE_PKG_RESOURCES;
49 }
50 #endif
51 
52 #ifdef CONFIG_SCHED_MC
cpu_core_flags(void)53 static inline int cpu_core_flags(void)
54 {
55 	return SD_SHARE_PKG_RESOURCES;
56 }
57 #endif
58 
59 #ifdef CONFIG_NUMA
cpu_numa_flags(void)60 static inline int cpu_numa_flags(void)
61 {
62 	return SD_NUMA;
63 }
64 #endif
65 
66 extern int arch_asym_cpu_priority(int cpu);
67 
68 struct sched_domain_attr {
69 	int relax_domain_level;
70 };
71 
72 #define SD_ATTR_INIT	(struct sched_domain_attr) {	\
73 	.relax_domain_level = -1,			\
74 }
75 
76 extern int sched_domain_level_max;
77 
78 struct sched_group;
79 
80 struct sched_domain_shared {
81 	atomic_t	ref;
82 	atomic_t	nr_busy_cpus;
83 	int		has_idle_cores;
84 	int		nr_idle_scan;
85 };
86 
87 struct sched_domain {
88 	/* These fields must be setup */
89 	struct sched_domain __rcu *parent;	/* top domain must be null terminated */
90 	struct sched_domain __rcu *child;	/* bottom domain must be null terminated */
91 	struct sched_group *groups;	/* the balancing groups of the domain */
92 	unsigned long min_interval;	/* Minimum balance interval ms */
93 	unsigned long max_interval;	/* Maximum balance interval ms */
94 	unsigned int busy_factor;	/* less balancing by factor if busy */
95 	unsigned int imbalance_pct;	/* No balance until over watermark */
96 	unsigned int cache_nice_tries;	/* Leave cache hot tasks for # tries */
97 	unsigned int imb_numa_nr;	/* Nr running tasks that allows a NUMA imbalance */
98 
99 	int nohz_idle;			/* NOHZ IDLE status */
100 	int flags;			/* See SD_* */
101 	int level;
102 
103 	/* Runtime fields. */
104 	unsigned long last_balance;	/* init to jiffies. units in jiffies */
105 	unsigned int balance_interval;	/* initialise to 1. units in ms. */
106 	unsigned int nr_balance_failed; /* initialise to 0 */
107 
108 	/* idle_balance() stats */
109 	u64 max_newidle_lb_cost;
110 	unsigned long last_decay_max_lb_cost;
111 
112 	u64 avg_scan_cost;		/* select_idle_sibling */
113 
114 #ifdef CONFIG_SCHEDSTATS
115 	/* load_balance() stats */
116 	unsigned int lb_count[CPU_MAX_IDLE_TYPES];
117 	unsigned int lb_failed[CPU_MAX_IDLE_TYPES];
118 	unsigned int lb_balanced[CPU_MAX_IDLE_TYPES];
119 	unsigned int lb_imbalance[CPU_MAX_IDLE_TYPES];
120 	unsigned int lb_gained[CPU_MAX_IDLE_TYPES];
121 	unsigned int lb_hot_gained[CPU_MAX_IDLE_TYPES];
122 	unsigned int lb_nobusyg[CPU_MAX_IDLE_TYPES];
123 	unsigned int lb_nobusyq[CPU_MAX_IDLE_TYPES];
124 
125 	/* Active load balancing */
126 	unsigned int alb_count;
127 	unsigned int alb_failed;
128 	unsigned int alb_pushed;
129 
130 	/* SD_BALANCE_EXEC stats */
131 	unsigned int sbe_count;
132 	unsigned int sbe_balanced;
133 	unsigned int sbe_pushed;
134 
135 	/* SD_BALANCE_FORK stats */
136 	unsigned int sbf_count;
137 	unsigned int sbf_balanced;
138 	unsigned int sbf_pushed;
139 
140 	/* try_to_wake_up() stats */
141 	unsigned int ttwu_wake_remote;
142 	unsigned int ttwu_move_affine;
143 	unsigned int ttwu_move_balance;
144 #endif
145 #ifdef CONFIG_SCHED_DEBUG
146 	char *name;
147 #endif
148 	union {
149 		void *private;		/* used during construction */
150 		struct rcu_head rcu;	/* used during destruction */
151 	};
152 	struct sched_domain_shared *shared;
153 
154 	unsigned int span_weight;
155 	/*
156 	 * Span of all CPUs in this domain.
157 	 *
158 	 * NOTE: this field is variable length. (Allocated dynamically
159 	 * by attaching extra space to the end of the structure,
160 	 * depending on how many CPUs the kernel has booted up with)
161 	 */
162 	unsigned long span[];
163 };
164 
sched_domain_span(struct sched_domain * sd)165 static inline struct cpumask *sched_domain_span(struct sched_domain *sd)
166 {
167 	return to_cpumask(sd->span);
168 }
169 
170 extern void partition_sched_domains_locked(int ndoms_new,
171 					   cpumask_var_t doms_new[],
172 					   struct sched_domain_attr *dattr_new);
173 
174 extern void partition_sched_domains(int ndoms_new, cpumask_var_t doms_new[],
175 				    struct sched_domain_attr *dattr_new);
176 
177 /* Allocate an array of sched domains, for partition_sched_domains(). */
178 cpumask_var_t *alloc_sched_domains(unsigned int ndoms);
179 void free_sched_domains(cpumask_var_t doms[], unsigned int ndoms);
180 
181 bool cpus_share_cache(int this_cpu, int that_cpu);
182 
183 typedef const struct cpumask *(*sched_domain_mask_f)(int cpu);
184 typedef int (*sched_domain_flags_f)(void);
185 
186 #define SDTL_OVERLAP	0x01
187 
188 struct sd_data {
189 	struct sched_domain *__percpu *sd;
190 	struct sched_domain_shared *__percpu *sds;
191 	struct sched_group *__percpu *sg;
192 	struct sched_group_capacity *__percpu *sgc;
193 };
194 
195 struct sched_domain_topology_level {
196 	sched_domain_mask_f mask;
197 	sched_domain_flags_f sd_flags;
198 	int		    flags;
199 	int		    numa_level;
200 	struct sd_data      data;
201 #ifdef CONFIG_SCHED_DEBUG
202 	char                *name;
203 #endif
204 };
205 
206 extern void __init set_sched_topology(struct sched_domain_topology_level *tl);
207 
208 #ifdef CONFIG_SCHED_DEBUG
209 # define SD_INIT_NAME(type)		.name = #type
210 #else
211 # define SD_INIT_NAME(type)
212 #endif
213 
214 #else /* CONFIG_SMP */
215 
216 struct sched_domain_attr;
217 
218 static inline void
partition_sched_domains_locked(int ndoms_new,cpumask_var_t doms_new[],struct sched_domain_attr * dattr_new)219 partition_sched_domains_locked(int ndoms_new, cpumask_var_t doms_new[],
220 			       struct sched_domain_attr *dattr_new)
221 {
222 }
223 
224 static inline void
partition_sched_domains(int ndoms_new,cpumask_var_t doms_new[],struct sched_domain_attr * dattr_new)225 partition_sched_domains(int ndoms_new, cpumask_var_t doms_new[],
226 			struct sched_domain_attr *dattr_new)
227 {
228 }
229 
cpus_share_cache(int this_cpu,int that_cpu)230 static inline bool cpus_share_cache(int this_cpu, int that_cpu)
231 {
232 	return true;
233 }
234 
235 #endif	/* !CONFIG_SMP */
236 
237 #if defined(CONFIG_ENERGY_MODEL) && defined(CONFIG_CPU_FREQ_GOV_SCHEDUTIL)
238 extern void rebuild_sched_domains_energy(void);
239 #else
rebuild_sched_domains_energy(void)240 static inline void rebuild_sched_domains_energy(void)
241 {
242 }
243 #endif
244 
245 #ifndef arch_scale_cpu_capacity
246 /**
247  * arch_scale_cpu_capacity - get the capacity scale factor of a given CPU.
248  * @cpu: the CPU in question.
249  *
250  * Return: the CPU scale factor normalized against SCHED_CAPACITY_SCALE, i.e.
251  *
252  *             max_perf(cpu)
253  *      ----------------------------- * SCHED_CAPACITY_SCALE
254  *      max(max_perf(c) : c \in CPUs)
255  */
256 static __always_inline
arch_scale_cpu_capacity(int cpu)257 unsigned long arch_scale_cpu_capacity(int cpu)
258 {
259 	return SCHED_CAPACITY_SCALE;
260 }
261 #endif
262 
263 #ifndef arch_scale_thermal_pressure
264 static __always_inline
arch_scale_thermal_pressure(int cpu)265 unsigned long arch_scale_thermal_pressure(int cpu)
266 {
267 	return 0;
268 }
269 #endif
270 
271 #ifndef arch_update_thermal_pressure
272 static __always_inline
arch_update_thermal_pressure(const struct cpumask * cpus,unsigned long capped_frequency)273 void arch_update_thermal_pressure(const struct cpumask *cpus,
274 				  unsigned long capped_frequency)
275 { }
276 #endif
277 
task_node(const struct task_struct * p)278 static inline int task_node(const struct task_struct *p)
279 {
280 	return cpu_to_node(task_cpu(p));
281 }
282 
283 #endif /* _LINUX_SCHED_TOPOLOGY_H */
284