Lines Matching refs:be
38 description: boolean, regulator should never be disabled
46 This property is intended to only be used for regulators where
55 description: allow the regulator performance level to be configured
60 disabling ramp rate, it should be explicitly initialised to zero (regulator-ramp-delay
102 for the regulator at run-time. Elements may be specified in any order.
123 hardware performs emergency shutdown. Zero can be passed to disable
124 protection and value '1' indicates that protection should be enabled but
125 limit setting can be omitted.
130 Zero can be passed to disable error detection and value '1' indicates
131 that detection should be enabled but limit setting can be omitted.
135 is assumed still to be functional but approaching limit where it gets
136 damaged. Recovery actions should be initiated. Zero can be passed to
138 be enabled but limit setting can be omitted.
142 hardware performs emergency shutdown. Zero can be passed to disable
143 protection and value '1' indicates that protection should be enabled but
144 limit setting can be omitted. Limit is given as microvolt offset from
150 Zero can be passed to disable error detection and value '1' indicates
151 that detection should be enabled but limit setting can be omitted. Limit
156 is assumed still to be functional but approaching limit where it gets
157 damaged. Recovery actions should be initiated. Zero can be passed to
159 be enabled but limit setting can be omitted. Limit is given as microvolt
164 hardware performs emergency shutdown. Zero can be passed to disable
165 protection and value '1' indicates that protection should be enabled but
166 limit setting can be omitted. Limit is given as microvolt offset from
172 Zero can be passed to disable error detection and value '1' indicates
173 that detection should be enabled but limit setting can be omitted. Limit
178 hardware is assumed still to be functional but approaching limit where
179 it gets damaged. Recovery actions should be initiated. Zero can be passed
181 be enabled but limit setting can be omitted. Limit is given as microvolt
186 hardware performs emergency shutdown. Zero can be passed to disable
187 protection and value '1' indicates that protection should be enabled but
188 limit setting can be omitted.
193 Zero can be passed to disable error detection and value '1' indicates
194 that detection should be enabled but limit setting can be omitted.
198 hardware is assumed still to be functional but approaching limit where it
199 gets damaged. Recovery actions should be initiated. Zero can be passed to
201 be enabled but limit setting can be omitted.
214 is 2-way - all coupled regulators should be linked with each other.
215 A regulator should not be coupled with its supplier.
228 that can be changed safely in a single step.
243 description: regulator should be on in suspend state.
247 description: regulator should be off in suspend state.
251 description: minimum voltage may be set in suspend state.
254 description: maximum voltage may be set in suspend state.
257 description: the default voltage which regulator would be set in
264 in suspend can be changed in runtime.