Lines Matching refs:threshold
6 Program sensor type for threshold detector inputs.
8 threshold detector input channel. Channels 0..7, 8..15, 16..23
16 Channel Y low voltage threshold. If sensor input voltage goes lower then
17 this value then the threshold falling event is pushed.
18 Depending on in_voltageY_sensing_mode the low voltage threshold
20 Channels 0..31 have common low threshold values, but could have different
23 The low voltage threshold range is between 2..21V.
27 If falling threshold results hysteresis to odd value then rising
28 threshold is automatically subtracted by one.
35 Channel Y high voltage threshold. If sensor input voltage goes higher then
36 this value then the threshold rising event is pushed.
37 Depending on in_voltageY_sensing_mode the high voltage threshold
40 Channels 0..31 have common high threshold values, but could have different
43 The high voltage threshold range is between 3..22V.
47 If rising threshold results hysteresis to odd value then falling
48 threshold is automatically appended by one.