4 Cirrus Logic LAN CS8900/CS8920 Ethernet Adapters
24 1.0 CIRRUS LOGIC LAN CS8900/CS8920 ETHERNET ADAPTERS
33 2.1 CS8900-based Adapter Configuration
59 1. Cirrus Logic LAN CS8900/CS8920 Ethernet Adapters
66 The CS8900-based ISA Ethernet Adapters from Cirrus Logic follow
73 CS8920-based adapters are similar to the CS8900-based adapter with additional
83 The CS8900/CS8920 Ethernet Adapter driver for Linux supports the Linux
111 * Cirrus Logic LAN (CS8900/20-based) Ethernet ISA Adapter
116 * One available IRQ (5,10,11,or 12 for the CS8900, 3-7,9-15 for CS8920).
125 * CS8900/20 Setup Utility (DOS-based)
154 Both the CS8900 and CS8920-based adapters can be configured using parameters
155 stored in an on-board EEPROM. You must use the DOS-based CS8900/20 Setup
163 Since the CS8900/20 Setup Utility is a DOS-based application, you must install
164 and configure the adapter in a DOS-based system using the CS8900/20 Setup
166 installing a CS8900-based adapter and the default configuration is acceptable.)
169 2.1. CS8900-based Adapter Configuration
172 CS8900-based adapters shipped from Cirrus Logic have been configured
187 CS8900/20 Setup Utility.
196 run the CS8900/20 Setup Utility to disable PnP and configure the
208 * RUN THE CS8900/20 SETUP UTILITY TO DISABLE PnP SUPPORT AND *
284 * CS8900 defaults to half-duplex if not specified on command-line
383 the CS8900/20 Setup Utility can be used to test the functionality of the
388 CS8900/20-based adapter card (it must also be running the CS8900/20 Setup
398 To run the diagnostics tests on the CS8900/20 adapter:
400 1. Boot DOS on the PC and start the CS8900/20 Setup Utility.
419 The IO Register Read/Write test insures that the CS8900/20 can be
424 The Shared Memory test insures the CS8900/20 can be accessed in memory
439 The Chip RAM test insures the 4K of memory internal to the CS8900/20 is
467 transferring data between two CS8900/20 adapters installed in different PCs
471 This test requires that each of the two PCs have a CS8900/20-based adapter
472 installed and have the CS8900/20 Setup Utility running. The first PC is
484 1. Select a PC with a CS8900/20-based adapter and a known working network
485 connection to act as the Responder. Run the CS8900/20 Setup Utility
489 2. Return to the PC with the CS8900/20-based adapter you want to test and
490 start the CS8900/20 Setup Utility.
521 of four ways after installing and or configuring the CS8900/20-based adapter:
534 If an IO conflict occurs, run the CS8900/20 Setup Utility and perform a
542 CS8900/20 Setup Utility. Once reinstalled in the target system, run the